Title: 951 SOUTH ANDREWS AVENUE
Attachments: 1. PZB Drawings 4-22-2026.zip, 2. PZB Documents 4-22-2026.zip
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.

boardname

PLANNING AND ZONING BOARD

Meeting Date: APRIL 22, 2026

 

title

951 SOUTH ANDREWS AVENUE

 

projectinfo

Request:                     Major Site Plan

P&Z#                     25-12000039

Owner:                     951 SW 12th LLC

Project Location:                     951 SW 12 Ave

Folio Number:                     494202000751 & 494202000754

Land Use Designation:                     I (Industrial)

Zoning District:                     I-1 (General Industrial)

Commission District:                     5 (Darlene Smith)

Agent:                      Mike Amodio

Project Planner:                     Saul Umana (954-786-5578 / saul.umana@copbfl.com)

 

otherinfo

 

 

Summary:                     

The applicant is seeking Major Site Plan approval to construct two new free-standing one-story warehouse buildings, each with approximately 6,630 SF of warehouse space and 1,482 SF of accessory office space, with parking provided near each building. The site currently has an 8,000-square-foot one-story warehouse. The site will also include approximately 69,480 square feet of outdoor storage.

 

As required by Code, the project must provide perimeter landscaping and screening of the outdoor storage. A Type C buffer, which includes an 8-foot masonry wall, is required along South Andrews Avenue (the front property line), and a Type A buffer is required along all other sides. While a wall is not required along the remaining perimeters, the outdoor storage material must be screened. The applicant has proposed chain-link fencing with screening slats along those sides. The site meets the minimum parking, pervious area, and vehicular use area landscaping requirements of the Zoning Code.

 

The project was granted a special exception approval via PZ#26-17000002 for the proposed outdoor storage. The project was reviewed by the DRC on December 29, 2025 and February 18, 2026.  The Architectural Appearance Committee approved the Building Design on April 7th, 2026.

 

SITE PLAN REVIEW STANDARDS

 

An application for a Major Site Plan shall be approved only on a finding that there is competent, substantial evidence in the record that the development, as proposed:

 

1. Is consistent with the land use designation in the comprehensive plan;

 

The property has a land use designation of I (Industrial). The proposed industrial development is a compatible use for this land use category. The Development is consistent with the City of Pompano Beach Comprehensive Plan, and the Future Land Use Element Goals, Objectives and Policies contained therein:

Policy 01.03.13

 Future industrial land uses shall be located with access to major transportation facilities, including highways, airports, railroads, and seaports.

Policy 01.14.01

The City shall emphasize redevelopment and infill, which concentrates the growth and intensifies the land uses consistent with the availability of existing urban services and infrastructure in order to conserve natural and man-made resources.

Policy 01.14.07.

All site plans will be reviewed for Crime Prevention Through Environmental Design (CPTED) design principles such as lighting, street design, natural surveillance, natural access control, and territorial reinforcement. CPTED infrastructure such as security lighting, security cameras, bollards, and other access control methods will be required based on the specific needs of the project.

Objective 01.02.00. Right-of-Way Protection and Accessibility. Protect the existing and future building encroachments and ensure proper accessibility with the roadway and transit network.

 

2. Complies with the applicable district, use, intensity and dimensional standards of this Code (Articles 3, 4, and 5);

Article 3: Zoning Districts

The subject property’s zoning land use is General Industrial (I-1). The proposal is consistent with land use goals, objectives and policies.

Article 4: Use Standards

The development proposes outdoor storage as a principal use with two new warehouse buildings for the purpose of warehousing, storage, and distribution. Both uses comply with the use

specific standards in Article 4: Use Standards and are consistent with the uses as permitted by the I-1 district. In addition, the project obtained special exemption approval for the outdoor storage via PZ#26-17000002.

Article 5: Development Standards

See section 3 below.

 

3. Complies with the applicable development standards of this Code (Article 5);

The DRC and the project applicant have worked extensively through multiple review cycles to produce a development that complies with the requirements of Article 5, including Access, Parking, and Loading; General Industrial (I-1) standards; and Sustainable Development standards. The project has obtained a Development Order for Building Design and received Superior Vernacular Design approval from the AAC for the required deviation from Section 155.5603.F.2 (Entrance). To comply with the landscaping buffer requirements under the Outdoor Storage standards, the chain-link fence and gate proposed at the entrance adjacent to N. Andrews Avenue must be removed and replaced with a masonry wall, as required by the Type C buffer standards

4. Complies with all other applicable standards in this Code;

The proposed site plan complies with the applicable Code standards.

5. Complies with all requirements or conditions of any prior applicable Development Orders;

The application has an actively approved Development Order for the Outdoor Storage as a principal use. The Development Order has conditions that must be satisfied concurrently with this Major Site Plan approval.

6. The concurrency review has been completed in accordance with Chapter 154 (Planning) of the Code of Ordinances;

Based on the estimated demand calculated below, the proposed project complies with concurrency requirements.

Wastewater Treatment Demand                              

1, 622.40 gallons per day*

Water Treatment Demand

1,924.17 gallons per day*

Raw Water Demand                                                 

2,078.10 gallons per day*

Park Acreage Required

N/A

School Impacts

Final Broward County School Capacity Availability Determination must be Provided.

Transportation

Transit fees are paid to Broward County to meet concurrency.

Solid Waste Generation

324.48 lbs. per day (City has a contract with Waste Management for disposal of all solid waste through 2033).

* The City has adequate capacity to serve the proposed project

7. Is designed to provide safe, adequate, paved vehicular access between buildings within the Development and streets as identified on the Broward County Trafficways Plan;

The development aims to provide safe, adequate, paved vehicular access between the proposed buildings and outdoor storage area and N Andrews Avenue. The project maintains the two existing driveway locations.

8. Complies with any applicable hazardous material licensing requirements in the Broward County Wellfield Protection Ordinance;

The Property is not located within a wellfield protection area.;

9. Complies with crime prevention, security strengthening, and CPTED standards for natural surveillance, natural access control, territorial reinforcement, maintenance, and activity support.

As part of the Major Site Plan and Building Design application, the applicant’s team has developed a separate CPTED security plan that addresses the CPTED standards for natural surveillance, natural access control, territorial reinforcement, maintenance, and activity support.

10. Complies with the adopted Fire Codes and Standards pursuant to City Code Section 95.02;

The proposed site plan was reviewed by a Fire Plans Examiner during DRC and must meet all applicable standards before building permits are approved.

11. Considers and mitigates any potential adverse impacts on environmentally sensitive lands identified by the City Comprehensive Plan or Broward County Land Use Plan.

The proposed development is not within an area that will have impact on environmentally sensitive lands as defined in the Broward County Land Use Plan.

12. Complies with the approved Transportation Corridor Study, unless in direct conflict with Another Zoning Code provision.

The proposed development is located not within the areas proposed as part of the approved Transportation Corridor Study.

DEPARTMENT RECOMMENDATION

Pursuant to §155. 2304.C, Applications Subject to Staff Recommendation, the Development Services Director has compiled the department reports from the Development Review Committee (DRC) meeting which are recorded on file with the Department. Should the Board find that the application has provided competent, substantial evidence to satisfy the review standards for Major Site Plan approval, the Development Services Department recommends approval of the Major Site Plan subject to the following comments and conditions:

 

1.                     Successfully satisfy all conditions of approval of the Special Exception Development Order PZ#26-17000002.

2.                     Provide a continuous curbing around all vehicular use areas to obstruct vehicular encroachment into required landscaping around the entire site.

3.                     The proposed chain-link fence along the middle driveway facing Andrews Avenue must be removed and replaced with a masonry wall, as required by the Type C buffer standards.

4.                     The proposed chain-link fence along the side streets must not be visible from the public right-of-way, pursuant to Code Section 155.5302.G.1.

5.                     Prior to building permit approval, provide a Unity of Title for the property.

6.                     Prior to building permit approval, the property shall be platted.

7.                     Standard Conditions of Approval and/or Specifications required prior to Building Permit / Zoning Compliance Permit issuance:

a) The applicant shall provide evidence of compliance for the 12 points listed in the Sustainability Narrative as submitted to the DRC in accordance with Table 155.5802: Sustainable Development Options and Points.

b) Plans are subject to compliance with all applicable Code requirements, including but not limited to DRC comments issued for this site plan.

c) Landscape and Irrigation Plans must comply with all Zoning Code requirements as verified by the City’s Urban Forestry Division.

d) Provide a photometric plan that complies with Code Section 155.5401: General Exterior Lighting Standards. The photometric plan shall include the outdoor storage areas. 

e) A copy of the CPTED plan approved by the Broward Sheriff’s Office must be submitted for Zoning