Meeting Date: DECEMBER 3, 2025

 

title

BIG TREE BBQ

 

projectinfo

Request:                     Minor Site Plan

P&Z#                     25-12000012

Owner:                     Pompano Beach Community Redevelopment Agency

Project Location:                     N Powerline Rd

Folio Number:                     484233020220; 484233020230; 484233020550; 484233020560; 484233040770

Land Use Designation:                     C (Commercial)

Zoning District:                     B-2 (Community Business)

Commission District:                     5 (Darlene Smith)

Agent:                      Paola West

Project Planner:                     Diego Guevara (954-786-4310 / diego.guevara@copbfl.com)

 

otherinfo

Summary:                     

The applicant is requesting approval of a Minor Site Plan for the construction of a new BBQ Restaurant building.  The property is located at the eastern side of the block located between NW 5th Street and NW 4th Court, along Powerline Road. The proposed restaurant has 1468 Sf., a covered outdoor patio with 400 sf., and 13 parking spaces, including two ADA.  The property, where the building is located, is within the Community Business (B-2) designated district. 

 

 

Staff Conditions:                      

PLANNING

Max Wemyss | max.wemyss@copbfl.com <mailto:max.wemyss@copbfl.com>

Status:                                           Pending Resubmit

 

1.                     Property is platted "Collier City" PB 31, Pg 1 (1953), which appears unrestricted in terms of uses or points of access.

2.                     The land use for this parcel is Commercial, and the zoning is B-2 (Community Business). The proposed use is Restaurant, which is listed as a permitted use in this zoning district.

3.                     Broward County Trafficways Plan requires a minimum of 144' (up to 164') feet on Powerline Road; the survey and site plan indicate that there is approximately 65 feet to the center line of the road, where a minimum of 72 feet will be required, thus additional dedications are required. Broward County Trafficways Plan is regulated by the Broward County Planning Council. Questions may be directed to 954-357-6695. Chapter 100 of the City's Code of Ordinances also requires the ROW to be a minimum of 144 feet in width. The City Engineer must confirm any variation from this.

4.                     Access to this site will be difficult to accommodate. Our code does not allow access to the property within 100 linear feet of the intersection with Powerline Road. Only one two-way driveway, or one pair of one-way driveways, is allowed onto lots with 200 or less feet of lot frontage on the arterial or collector street.
A variance may be the only appropriate path to accommodate the proposal. A variance will be required prior to development order issuance.

5.                     Should a one-way exit to the south be permitted, vehicles can only exit to the east as a west or left turn is prohibited by the constructed traffic diverter.

6.                     A Type C buffer (Sec 155.5203.F) is required as a residential compatibility standard.

7.                     The city has sufficient water and wastewater treatment capacity to accommodate the proposal.

 

 

ZONING

Diego Guevara | diego.guevara@copbfl.com <mailto:diego.guevara@copbfl.com>

Status:                                             Pending Resubmit

 

Provide a written response to all comments.

 

1.                     The proposed south access driveway does not comply with Sec. 155.5101.G.3 Vehicular Access Management. This provision of the Code requires any driveway access to be at least 100 feet from the intersection of a principal arterial street, minor arterial street, or collector designated on the Broward County Trafficways Plan. The driveway will create a potential traffic conflict with the existing traffic pattern of the area. The applicant must obtain a relief from ZBA and approval from Broward County and Florida DOT.

2.                     Provide a drawing showing the VUA area with a hatch or a color, include the square footage of the hatched/colored area.

3.                     Revise the buffer types listed. In the previous DRC review meeting we established the need to provide a Type C buffer on the southern parcel as required by Sec. 155.5604 Residential Compatibility Standards. The site plan list all the buffer areas as Type B.

 

 

UTILITIES

Nathaniel Watson | nathaniel.watson@copbfl.com <mailto:nathaniel.watson@copbfl.com>

Status:                                                  Pending Resubmit                            

 

1.                     Additional comments may be forthcoming contingent upon future submittals to the PAM and/or DRC review process.

2.                     Please procure an approved Broward County EPD Surface Water Management permit or exemption for the proposed site and off-site work. Required during official Bldg. E-plan submittal.

3.                     Please follow best management practices for sedimentation and erosion control of on-site and off-site storm systems.

4.                     Please note that as 50.02 WATER DISTRIBUTION; GENERAL. (B) (7) All new dedicated fire line connections to private property shall be provided with an approved type fire line meter that has been tested in accordance with AWWA standards. The meter shall be capable of accurately recording flow. The customer shall pay all costs involved in the installation of the fire line and meter. The meter shall be installed by the city. This shall be a City meter before the DDCV and not a meter associated with the DDCV.

5.                     Civil plan 013 C2 WSS proposes a 2 domestic water tap with a 1 water meter, which is not to the City Engineering Standard detail. Propose a 1 water metered connection as per detail 107-1 Typical 1" Water Service or a 2 water metered connection as per detail 107-2 Typical 2" Water Service. Please correct.

6.                     Please attach the following City Engineering Standard detail as it applies: 106-3 Fire Meter and Backflow Device, 107-2 Typical 2" Water Service, 200-1 Service Laterals with Risers, 210-3 Sewer Box and Cover Heavy Traffic, 315-1 Typical Screen For Utilities, 316-1 Required Tree Locations. 

As noted previously, please attach 106-3 Fire Meter and Backflow Device, 107-2 Typical 2" Water Service. Please refer to comment #4 regarding the proposed fire service, which is shown as 4" fire service on 013 C2 WSS Plan. Please correct.

7.                     Please note that any proposed metered service 3 or larger is not a stock item. These meters are subject to a 6 to 8-month order lead time. Please order these items promptly to ensure the services are available for installation.

 

 

URBAN FORESTRY

Wade Collum | wade.collum@copbfl.com <mailto:wade.collum@copbfl.com>

Status:                                           Pending Development Order

 

 

FIRE DEPARTMENT

Jim Galloway | jim.galloway@copbfl.com <mailto:jim.galloway@copbfl.com>

Status:                                           Pending Development Order

 

 

ENGINEERING DEPARTMENT

David McGirr | david.mcgirr@copbfl.com <mailto:david.mcgirr@copbfl.com>

Status:                                            Pending Development Order

 

 

BSO

Anthony Russo | anthony_russo@sheriff.org <mailto:anthony_russo@sheriff.org>

Status:                                    Pending Development Order

 

 

BUILDING DIVISION:

Todd Stricker | tod.stricker@copbfl.com <mailto:tod.stricker@copbfl.com>

Status:                                           Pending Development Order