File #: LN-772    Version: Name:
Type: DRC Submission Status: Regular Agenda Ready
File created: 8/6/2025 In control: Development Review Committee
On agenda: 10/15/2025 Final action:
Title: RISING TIDE CAR WASH
Attachments: 1. DRC Documents_08.20.2025.zip, 2. DRC Drawings_08.20.2025.zip, 3. DRC Drawings_10.15.2025.zip, 4. DRC Documents_10.15.2025.zip
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.

boardname

DEVELOPMENT REVIEW COMMITTEE

Meeting Date: OCTOBER 15, 2025

 

title

RISING TIDE CAR WASH

 

projectinfo

Request:                     Minor Site Plan

P&Z#                     25-12000026

Owner:                     Racetrac Petroleum INC & Silver Oak Advisors

Project Location:                     2901 W Atlantic Blvd

Folio Number:                     484233450010

Land Use Designation:                     C (Commercial)

Zoning District:                     B-3 (General Business)

Commission District:                     5 (Darlene Smith)

Agent:                      Paola West

Project Planner:                     Jonathan Cady (954-786-5578 / jonathan.cady@copbfl.com)

 

otherinfo

 

Summary:                     

The applicant is requesting MINOR SITE PLAN approval to develop a new 3,500 sq. ft. express car wash and related site and landscape modifications, including 500 sq. ft. of covered vacuuming spaces. The property is 52,371 sq. ft. (1.20 acres) and is located north of Atlantic Boulevard, between NW 30th Avenue and NW 28th Avenue within the City of Pompano Beach. The site is currently vacant.

 

Staff Conditions:                      

PLANNING

Max Wemyss | max.wemyss@copbfl.com

Status: Pending Development Order

 

1.                     The property is platted (Engstrom Plat; ORB 152 Pg 45). The plat restricts the development to 10,000 square feet of commercial use. This plat note was amended to restrict to a service station with 18 fuel positions and a convenience store. A new amendment application has been processed through the City (PZ25-14000004) to provide a note that states: THIS PLAT IS RESTRICTED TO A 10,000 SQUARE-FOOT AUTOMATED CAR WASH. This amended note allows the proposed use. The site plan table indicates the proposed development will be approximately 3,500 square feet. (Info Only).

2.                     Land use for this parcel is Commercial (C), and the proposed use is permitted in the land use category. (Info Only).

3.                     Broward County Trafficways Plan requires a minimum of 120 feet on West Atlantic Blvd; the survey indicates that there is 120 feet & thus no additional right-of-way is required. NW 30th is a commercial road, not specifically listed in the Trafficways Plan or Code of Ordinances & thus the 60 feet provided is sufficient. NW 1st street is both residential and commercial, where a minimum of 30 feet to the centerline would be required on the south side, consistent with existing dedications. (Info Only).

4.                     The city has sufficient capacity to accommodate the proposal. (Info Only).

 

 

ENGINEERING DEPARTMENT

David McGirr | david.mcgirr@copbfl.com

Status: Pending Development Order

 

1.                     The conceptual water and sewer civil plan design lacks essential details. It requires meticulous attention to detail and specific delineation of the adjacent City mains, sizes, and connection characteristics. (Condition)

2.                     Submit/upload a copy of the (FDOT) Florida Department of Transportation driveway connection permit or exemption for the proposed driveway, roadway curb gutter, and sidewalk to be constructed within the road right-of-way of W. Atl. Blvd. (Condition)

3.                     Submit/upload a copy of the (FDOT) Florida Department of Transportation driveway drainage connection permit or exemption for the proposed driveway, roadway curb gutter, and sidewalk to be constructed within the road right-of-way of W. Atl. Blvd. (Condition)

4.                     Submit/upload a copy of the (FDOT) Florida Department of Transportation utility construction permit or exemption for the proposed off-site potable water, reclaimed water, and sewer main or lines to be constructed within the road right-of-way of W. Atl. Blvd. (Condition)

5.                     Submit/upload the (FDEP) Florida Department of Environmental Protection NPDES General Permit for the proposed stormwater discharge from the proposed site construction activities. (Condition)

6.                     Submit/upload the (FDEP) Florida Department of Environmental Protection (NOI) Notice of Intent for the proposed stormwater discharge from the proposed site construction activities. (Condition)

7.                     Place note on landscape plans as per City Ordinance(s) 50.02(A) (3) and 100.35(G) that landscaping materials other than sod are not allowed within (5') five feet of any portion of City-owned utilities within the public street right-of-way including meters, hydrants, service lines, etc. Also, please note that no trees, shrubbery, or obstructions shall be placed within a 3 radius of a City-owned sewer lateral cleanout or water &/or reuse meter. Show the location of all existing city-owned and maintained potable water mains and services, sanitary sewer mains or laterals, and storm drainage lines on the proposed landscape plans. Contact Tracy Wynn, GIS Coordinator, Engineering Division, for Utility information. 954-545-7007 tracy.wynn@copbfl.com Engineering Standard street tree detail 316-1 and 315-1. (Info Only).

 

PLEASE PROVIDE A NARRATIVE RESPONSE TO THESE REVIEW COMMENTS (IF APPLICABLE), SEE MARKUPS (IF REFERENCED) AND CLEARLY SHOW CHANGES ON PLANS USING CLOUDED DETAILS AND DELTA REVISION MARKS AS NECESSARY.

**** Please note - the City Engineering Division may issue additional review comments throughout the remainder of the permitting process while the civil engineering plans are finalized for this project. ****

 

FIRE DEPARTMENT

Jim Galloway | jim.galloway@copbfl.com

Status: Pending Development Order

 

No Comments have been rendered as of October 2nd, 2025.

 

BUILDING DIVISION

Todd Stricker | todd.stricker@copbfl.com

Status: Pending Development Order

 

Advisory Comments


A preliminary examination of the documents has been performed; additional comments may apply when completed plans and/or specifications have been submitted for permitting to the building department.
Buildings shall comply with all local, state and federal codes in effect at time of application, including FEMA Floodplain, NPDES and HVHZ regulations.

FBC_BCA 105.2.3 Public service agencies/other approvals. The building official shall require that the laws, rules and regulations of any other regulatory AHJ, and where such laws, rules and regulations are applicable and are known to the building official, shall be satisfied before a permit shall be issued. The building official shall require such evidence, as in his or her opinion is reasonable, to show such other approvals.

City Ordinance 53.16(A)(1) Construction sites and construction activities. construction sites and operations shall be required to maintain during and after all construction, development excavation or alteration operations, structural and non-structural best management practices with the intent to reduce pollutants and sediment in stormwater runoff.

City Ordinance 152.06(A): If applicable, contractor shall provide temporary screened fence complying with City Ordinance 152.06(B) through 152.06(G).

FBC 3306.1 Pedestrians shall be protected during construction, remodeling and demolition activities as required by this Chapter and Table 3306.1. Signs shall be provided to direct pedestrian traffic.

City Ordinance 152.25(A) Site plans and construction documents, Information for development in areas with base flood elevations. The site plan or construction documents for any development subject to the requirements of the floodplain regulations shall be drawn to scale and shall include, as applicable to the proposed development all sections from: City Ordinance 152.25 (A)(1) thru City Ordinance 152.25 (A)(7). Delineation of flood hazard areas, floodway boundaries and flood zone(s), base flood elevation(s), and ground elevations if necessary for review of the proposed development, etc. residential buildings shall comply with City Ordinance 152.29(C)(1)(A).

FHA Title VIII of the Civil Rights Act of 1968, commonly known as the Fair Housing Act, prohibits discrimination in the sale, rental, and financing of dwellings based on race, color, religion, sex, and national origin. In 1988, Congress passed the Fair Housing Amendments Act. The Amendments expand coverage of Title VIII to prohibit discriminatory housing practices based on disability and familial status. Now it is unlawful to deny the rental or sale of a dwelling unit to a person because that person has a disability.

FBC A201.1 This code establishes standards for accessibility to places of public accommodation and commercial facilities by individuals with disabilities. All new or altered public buildings and facilities, private buildings and facilities, places of public accommodation and commercial facilities subject to this code shall comply with 2020 FBC Accessibility.

FBC A221.1.1 Florida vertical accessibility. Nothing in this code relieves the owner of any building, structure, or facility governed by this code from the duty to provide vertical accessibility to all levels above and below the occupiable grade level, regardless of whether the ADA standards for accessible design require an elevator to be installed in such building, structure or facility.

FBC A206.2.1 Site arrival points. At least one accessible route shall be provided within the site from accessible parking spaces complying with FBC A502 and accessible passenger loading zones complying with FBC A209; public streets and sidewalks; and public transportation stops to the accessible building or facility entrance they serve.

FBC_BCA 107.3.4.0.6 Compliance with the specific minimum requirements of this code shall not be in itself deemed sufficient to assure that a building or structure complies with all of the requirements of this code. it is the responsibility of the architect and/or engineer of record for the building, structure or facility to determine through rational analysis what design requirements are necessary to comply with 2020 FBC.

1.                     FBC_BCA 107.1 As per the building official, separate building applications will be required for erosion control, site work, temporary fences, monumental signage and miscellaneous site structures.

2.                     FBC [F] 903.2 The enforcing agency will require that all provisions for an approved automatic sprinkler systems in new buildings and structures be provided in the locations described in sections 903.2.1 through 903.2.12 if applicable.

3.                     FBC 701.1 The enforcing agency will require that the provisions of this chapter, governing the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated construction separation of adjacent spaces to safeguard against the spread of fire and smoke within a building and the spread of fire to or from buildings, comply with this section of the code.

4.                     FBC 703.2 Fire-resistance ratings. Where materials, systems or devices that have not been tested as part of a fire-resistance-rated assembly are incorporated into the building element, component or assembly, sufficient data shall be made available to the building official to show that the required fire-resistance rating is not reduced. Materials and methods of construction used to protect joints and penetrations in fire-resistance-rated building elements, components or assemblies shall not reduce the required fire-resistance rating.

5.                     FBC 1003.1 The enforcing agency will require that all general requirements specified in sections 1003 through 1013, applicable to all three elements of the means of egress system, in addition to those specific requirements for the exit access, the exit and the exit discharge, comply with this section of the code.

6.                     FBC_BCA 107.1.1 The enforcing agency will require a life safety plan illustrating the floor area with proposed alterations with each room labeled. indicate construction type, fire rated walls, occupancy type: (current and proposed), occupancy load, means of egress, common path/travel distance/dead end corridor limits, accessibility accommodations including areas of refuge if applicable, emergency lighting, exits/exit signage, fire extinguishers, smoke alarms, fire suppression system and pull stations if applicable. Also provide tested design from accepted agency for rated walls and penetration details.

7.                     FBC_BCA 107.3.5.6 The enforcing agency will require product approvals be reviewed and approved by the building designer prior to submittal to verify that such products comply with the design specifications. Reviewed and approved product approvals shall then become part of the plans and/or specifications. Product approval shall be filed with the building official for review and approval prior to installation.

8.                     FBC_BCA 107.3.5.2 The enforcing agency will require that all shop drawings, (i.e. components attached to building structure, trusses/joists, window walls, railings, awnings, chutesetc), necessary to show compliance with applicable codes; shall be approved by the architect or professional engineer and submitted to the building official prior to installation.

9.                     F.S. 481.221(2) The enforcing agency will require digital signature panel to be active on all documents submitted for review to authenticate the serial number matches the submitted ESA. F.A.C. 61g1-16.005 Each sheet is required to be digitally or electronically signed, and bear the impress seal of, an architect or engineer (FBC_BCA 107.3.4.0.1).

10.                     FBC_BCA 107.3.4.0.8 All plans and/or specifications prepared by an architect or an engineer pursuant to the requirements of this code shall be hand signed, dated and sealed.

11.                     FBC_BCA 110.10.1 The enforcing agency will require a special inspector for various components of the building as determined by the building official. Building dept. will require special inspector form be completed and submitted for approval.

12.                     FBC_BCA 110.7 For threshold buildings, shoring and associated formwork or false work shall be designed and inspected by an engineer, employed by the permit holder or subcontractor, prior to any required mandatory inspections by the threshold building inspector.

13.                     FBC_BCA 110.8.1 The enforcing agency shall require a special inspector to perform structural inspections on a threshold building pursuant to a structural inspection plan prepared by the engineer or architect of record. The structural inspection plan must be submitted to the enforcing agency prior to the issuance of a building permit for the construction of a threshold building.

14.                     FBC 1512.3.1 The enforcing agency will require that all new roofing construction, including recovering and reroofing, repair or maintenance shall have A HVHZ uniform roofing permit application, as established by the authority having jurisdiction, completed and executed by a licensed contractor.

Fbc 1512.3.2 The uniform roofing permit shall include calculations in accordance With Chapter 16 (High-Velocity Hurricane Zones) of this code, unless the roofing assembly is less than the height/pressure threshold allowed in the applicable protocols herein.

15.                     FBC A208.2 Minimum number. Parking spaces complying with 502 shall be provided in accordance with table 208.2 except as required by 208.2.1, 208.2.2, and 208.2.3. Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking facility.

16.                     FBC A208.2.3.3 Parking for guests, employees, and other non-residents. Where parking spaces are provided for persons other than residents, parking shall be provided in accordance with table 208.2.

17.                     FBC A502.6 The enforcing agency will require parking space identification comply with the following code: signs shall include the international symbol of accessibility complying with FBC A703.7.2.1. Signs identifying van parking spaces when required By FBC A502.2 shall contain the designation Van Accessible. Reference Engineering Standard 300-5.

18.                     FBC 3303.5 Water Accumulation. The enforcing agency will require provisions be made to prevent the accumulation of water or damage to any foundations on the premises or the adjoining property.

19.                     1804.4 Site Grading. The ground immediately adjacent to the foundation shall be sloped away from the building at a slope of not less than one unit vertical in 20 units horizontal (5-percent slope) for a minimum distance of 10 feet measured perpendicular to the face of the wall. If physical obstructions or lot lines prohibit 10 feet of horizontal distance, a 5-percent slope shall be provided to an approved alternative method of diverting water away from the foundation. Swales used for this purpose shall be sloped a minimum of 2 percent where located within 10 feet of the building foundation. Impervious surfaces within 10 feet of the building foundation shall be sloped a minimum of 2 percent away from the building.

20.                     FBC_BCA 110.13.2.1 It shall be the joint responsibility of any owner of real property upon which construction is occurring, and any contractor responsible for said construction, to ensure that all road rights-of-way remain free at all times of all construction waste and trash resulting from such construction, and that all waste and trash resulting from the construction are contained on the real property upon which the construction occurs.

21.                     FBC_BCA 109.3 Building Permit Valuations. The applicant for a permit shall provide an estimated permit value at a time of application. Permit valuations, shall include total value of work, including materials and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment and permanent systems.

22.                     FBC_BCA 110.8.5.4 All plans for the building which are required to be signed and sealed by the architect or engineer of record contain a statement that, to the best of the architects or engineers knowledge, the plans and specifications comply with the applicable minimum building codes and the applicable fire-safety standards as determined by the local authority in accordance with this section and chapter 633, Florida Statutes.

BSO

Anthony Russo | Anthony_Russo@sheriff.org

Status: Pending Development Order

 

Development Review Committee Date Reviewed: 09-18-2025
Subject: CPTED and Security Strengthening Report: PZ#: 25-12000026
Name: Rising Tide Car Wash
Address / Folio: 2901 W. Atlantic Blvd., Pompano Beach, FL
Type: Minor Site Plan

Reviewer: BSO Deputy T. Russo for the City of Pompano Beach
Reviewer: BSO Deputy D. Cappellazo for the City of Pompano Beach
anthony_russo@sheriff.org
M-(561) 917-4556 (Send Text & Email, No Voicemail)
Tuesday Friday; 8 AM 3 PM
david_cappellazo@sheriff.org
M-(954) 275-7479 (Send Text & Email, No Voicemail)
Monday Thursday; 8 AM 3 PM


A. **DISCLAIMER**
SAFETY & SECURITY REVIEWS do not guarantee a crime will never occur; it is an effort to mitigate opportunities for crime & to help avoid any present & future security deficiencies, conflicts, threats, breaches, or liabilities that might occur without any review.

B. **PLEASE NOTE**
When a Broward Sheriffs Office CPTED Practitioner is required to assist in an inspection of the project during the Certificate of Completion &/or Certificate of Occupancy Application Phase, Security Strengthening & CPTED measures that have not been adequately addressed will still be required to ensure the safety & well-being of the employees, residents, tenants, visitors & all legitimate users of the site.

C. **BROWARD SHERIFFS OFFICE NO TRESPASSING PROGRAM**
Please note that participation in the BSO No Trespassing Program is required. If this site is already on the program, then additional signage may be necessary along with an updated affidavit signed by authorized personnel. Please contact the BSO Pompano Beach C.P.T.E.D Advisor regarding placement of the No Trespass Signs.

 

 

UTILITIES

Nathaniel Watson| Nathaniel.Watson@copbfl.com

Status: Resubmittal Required

 

1.                     Additional comments may be forthcoming contingent upon future submittals to the PAM and/or DRC review process. (Info Only).

2.                     Please procure an approved Broward County EPD Surface Water Management permit or exemption for the proposed site and off-site work. Required during the official Bldg. E-plan submittal. (Condition).

3.                     Please follow best management practices for sedimentation and erosion control of on-site and off-site storm systems. (Condition).

4.                     The proposed 3 water main or service shown on civil plan 042 C116 Utility is not permitted. The main/service line shall be 4. Please correct.

5.                     Please note that the proposed 3 water meter shall be an above-ground meter with a DDCV.

6.                     The proposed water service on civil plan 042 C116 Utility must show an 8 X 4 ductile iron mechanical joint tapping sleeve with a 4 resilient seated gate valve boxed to grade. The fitting before the meter connection shall be a 4 X 3 reducer. Please note on 042 C116 Utility plan.

7.                     The proposed meter must be located just behind the recorded property line. Please correct.

8.                     Please note on Landscape plan 021 L-200 Plating Plan that, as per City Ordinance(s) 50.02(A) (4) and 100.35(E), street trees shall not be placed on top of or 5of either side of any City-owned utility infrastructure. Also, please note that no trees, shrubbery, or obstruction shall be placed within a 3 radius of a City-owned sewer lateral cleanout or water &/or reuse meter.

9.                     Please indicate the estimated daily water consumptive use of the development in (GPD) gallons per day on Civil plan 042 C116 Utility.

10.                     Please indicate the estimated daily wastewater discharge of the development in (GPD) gallons per day on Civil plan 042 C116 Utility.

11.                     Please attach the following 2025 City Engineering details as they apply: 102-1 Valve Box Settings, 103-1 Gate or Valve Plug Settings, 106-2 Master Meter and Backflow Device, 106-4 Meter Install Dimensions List, 115-1 Underground Valve Identification Marker, 200-1 Service Laterals with Risers, 210-3 Sewer Box and Cover Heavy Traffic, 315-1 Typical Screen For Utilities, 316-1 Required Tree Locations.

12.                     Please note that the proposed 3 master meter is not a stock item and is subject to an order lead time. In relation to your construction schedule, please order the meter as soon as possible from the Citys Customer Service Department to ensure a timely installation. Order lead times can be up to 4 months. (Info Only).

13.                     Civil plans 038 C112 Paving & Grading and 042 C116 Utility Plan are missing. Please upload these drawings for review consideration.

 

LANDSCAPE REVIEW

Mark Brumet | mark.brumet@copbfl.com

Status: Pending Development Order

 

1.                     Please just note how mitigation is going to be handled.

2.                     As per 155.4219 note all Type B Buffer along all other perimeters on the plans and provide a cross section detail.

3.                     Provide Street Trees at 1:40’ as per 155.5203.G.2.c. along NW 30 Av. Relocate the sidewalk to against the property line to allow proper planting space. Street trees are required in the ROW along NW 30th Ave.

4.                     As per 155.5203.D.4., a landscaped island shall be provided at each end of every row of parking spaces and per every 10 spaces. Landscape parking islands are to be a minimum 8’ wide and contain trees, sod and irrigation, in location where 13 spaces are shown on either side of the south drive aisle. Middle teardrop island.

5.                     Please provide a detailed comment response sheet as to specifically how comments have been addressed at time of permit submittal.

6.                     Additional comments may be rendered a time of permit submittal.

7.                     All shrubs associated with the Type B Buffer are required to be 4' tall, please correct.

 

ZONING

Jonathan Cady | Jonathan.Cady@copbfl.com

Status: Resubmittal Required

 

1.                     Please provide a comment response sheet with a narrative response addressing all comments received in this DRC review. The response should be organized in a point-by-point format, referencing each comment and explaining how it has been addressed or revised in the resubmittal. (Info Only).

2.                     Please provide parking space numbers for each individual parking stall on the site plan. Based on the submitted plan, it appears there may be 30 or 32 parking spaces, whereas the site data table states there are 31. Numbering each space will help confirm the correct total and ensure consistency with the site data table.

                     The vacuum spaces located near the car wash exit are not designated parking spaces and therefore should not be counted toward the required parking total. These areas are intended solely for vehicle vacuuming and temporary use, not for long-term or customer/employee parking. Please update the site plan and parking calculations accordingly to reflect this distinction.

3.                     The site plan incorrectly states that the property is located within the County’s utility service area. However, the site is actually within the Pompano utility service area. Please update the plans to reflect this correction and ensure that any other references to the County's utility service area are also updated accordingly.

                     Comment not addressed. Site Data section on the Site Plan still states that the Water/Wastewater service is Broward County WWD. Please update and correct to the accurate Water/Wastewater service provider.

4.                     Per Section 15.4219.H.3.b., no overhead doors shall face the front lot line. Based on renderings and plans, it appears that the proposed bifold doors do, in fact, face the front lot line. To potentially comply with this regulation, provide screening by adding a wall as a cover of the service bay entrances Per Section 155.5602.C.7.c., Street-facing facades of the ground level floor for uses involving repair, servicing and/or maintenance shall not include service bay entrances, overhead doors, sliding glass doors, removable panels, or similar type of doors. Based on the layout of your site, NW 30th Avenue is the front lot line. This will officially determine whether your proposal will qualify as a superior design alternative. Refer to Section 155.2408.E. for the standards and procedures.

                     Provide an additional angle that demonstrates that the proposed wall screens the service bay entrances so that it doesn't face the front lot line. Also, although the 6' precast concrete site wall is called out, it's difficult to see where this wall begins and ends. Please clarify and bold the line that represents the wall so it's easy to comprehend.

5.                     Per Section 155.5602.C.7.a., at least 30 percent of the street-facing facade area of the ground-level floor of buildings (as measured from the grade to the underside of the eave, top of the parapet, or the story line denoting the second floor) shall be occupied by windows or doorways. Please update the elevation drawings to clearly demonstrate how the proposed design complies with this regulation. Be sure to indicate the specific features or dimensions that show how the requirement is being met.

                     The applicant is currently requesting approval of a superior design alternative at the Architectural Appearance Committee (AAC). Please note that if the proposed design is denied at AAC, you may be required to reapply through the Development Review Committee (DRC) process, especially if the denial results in substantial design revisions. (Condition).

6.                     Per Section 155.5509, In all new development, as well as redevelopment that increases gross floor area by 50 percent or more, all overhead utilities located on the development site and/or along the public right-of-way fronting the development site shall be placed underground to the maximum extent practicable-provided that the Development Services Director shall waive this requirement where the relevant utility company demonstrates that undergrounding will be detrimental to the overall safety and/or reliability of the circuit. Note on all plans that all overhead utilities located on the development site and/or along the public right-of-way fronting the development site shall be placed underground to the maximum extent practicable. Provide evidence and note on plans and in narrative that all overhead utilities will be buried for this project as per 155.5509. (Condition).

7.                     Per Section 155.9401.(G), The height of a structure shall be determined by measuring the vertical distance from the average elevation of the existing finished grade at the front of the structure to the top of the roof for a flat roof, to the deck line for a mansard roof, or to the mean height between eaves and ridge for a gable, hip, cone, gambrel, or shed roof. Ensure the elevation plan and how the elevation is measured comply with this. The height measurement should begin from the average elevation of the existing finished grade at the front of the structure.

                     Comment not addressed. The building height must be measured from the finished grade, not from the first floor as currently shown on the submitted elevation. Please revise the elevation drawings to begin the height measurement from the correct point in accordance with the zoning code. Refer to Figure 155.9401.G for a visual illustration of how height should be measured and shown.

8.                     Please provide a cross-access easement on the site plan, as the project is proposing access to the adjacent parcel on the left. This easement is necessary to formalize shared access and ensure compliance with regulations.

                     Provide the document for the previously approved cross-access agreement.

9.                     Per Section 155.5203.D.4.b., A landscaped island shall be provided at each end of every row of parking spaces. Where a row of parking spaces contains ten or more parking spaces, additional landscaped islands shall be provided at a spacing no greater than one every ten parking spaces. Each landscaped island shall be at least eight feet wide and at least as long as the adjacent parking spaces, with the long axis of the landscaped island running approximately parallel to that of the adjacent parking spaces. Each landscaped island shall contain at least one canopy tree. Understory trees may be substituted for canopy trees in areas beneath overhead utility lines. Trees shall be maintained to provide maximum canopy crown. Ensure that the proposed site complies with this regulation.

                     Although landscape islands have been provided for the parking spaces along the front of the property, please note that the parking spaces along the property line are also required to include landscape islands in accordance with zoning regulations. These landscape features are necessary to break up continuous rows of parking and enhance site aesthetics and environmental compliance. Please update the site plan to include landscape islands and ensure that the entire site complies with this regulation.

10.                     The site data table should include the Lot Coverage and Impervious/Pervious calculation. Please note that the canopy area should be included within the lot coverage.

                     Please provide the impervious and pervious surface area calculations directly on the Site Data Table within the site plan. Be sure to break down the calculations clearly, showing both the square footage and percentage of impervious and pervious areas to confirm compliance.

11.                     Please confirm whether the wall along NW 1st Street is located on the property line. The wall is required to be placed in the middle of the landscape buffer, not along the edge. If the wall is currently located directly on the property line, it will need to be relocated to comply with this requirement.

                     Comment not addressed. Prior to Zoning approval, the request to modify the required buffer must first be approved. If this request is not approved, you will need to revise the plans to comply with the original buffer requirements, as outlined in the previous comment. Please note that there may be issues with the buffer modification request, and a revised plan may be necessary. To avoid delays, we recommend addressing the potential outcome now by either securing approval of the buffer modification or updating the plan to meet the standard buffer regulations.

12.                     Please note per section 155.5602.C.7.b., that all ground-level windows on street-facing facades shall be transparent. Mirrored or heavily-tinted glass that prevents views into the building is prohibited on street-facing front building facades. (Info Only).

13.                     Please note that the front of the property is along NW 30th Avenue; therefore, when showing setback dimension on the plan, ensure that the setback demonstrates the correct layout of the plan.  (Info Only).

14.                     Please note that if this project proposes a security wall that includes lights, Wall packs on buildings may be used at entrances to a building to light unsafe areas, pursuant to Section 155.5401.I. They are not intended to draw attention to the building or provide general building or site lighting. Wall packs on the exterior of the building shall be fully shielded (e.g., with true cut-off type bulb or light source not visible from off-site) to direct the light vertically downward and have a light output of 900 lumens or less. Provide a detailed sheet that is fully shielded. (Info Only).

15.                     Please note that the proposed signs, although included with this submittal, would not be concurrently approved with this Minor Site Plan if approved and will need a separate building permit approval. (Info Only).

16.                     Please note that additional comments may be provided based on your next submittal, especially if revisions reveal items that were not previously reviewed or addressed. (Info Only).

17.                     Please note that once the vacant lot to the right of the subject property is developed, the entry gates on the subject property must be removed to comply with the existing cross-access easement. This requirement ensures unobstructed shared access between properties, as intended by the easement agreement. Be sure to account for this condition in the project planning and coordination moving forward. (Info Only).

18.                     Please ensure that all lines on the site plan are clearly labeled for clarity during review. Additionally, use different line weights to distinguish between the proposed fence and wall. Specifically, call out the proposed fence and wall, clearly indicating where each begins and ends.

19.                     Based on the submitted plans and the way the site is currently laid out, the circulation does not appear to be functional, particularly in relation to entering and exiting the lot, exiting the car wash, and simultaneously using the cross-access easement to the east. The proposed layout raises concerns about how vehicles will navigate the site, especially during peak use. For example, if all three vacuum spaces are occupied, it is unclear how a vehicle exiting the car wash would be able to exit the site safely and efficiently without obstruction. This situation could lead to traffic congestion or operational challenges on-site. Please clarify the proposed circulation pattern and how vehicle flow is intended to function under typical and peak conditions. If necessary, revise the site plan to improve circulation and address these concerns, ensuring that vehicles can move safely and efficiently throughout the site without interference from bottlenecks or blocked access points.

20.                     Please update the Site Data Table to ensure that all setback references are associated with the correct sides of the lot, based on the directional orientation of the property. Specifically:

                     NW 30th Avenue should be identified as the Front of the lot.

                     NW 1st Street should be labeled as the East side of the lot.

                     W Atlantic Boulevard should be labeled as the West side of the lot.

The current setbacks appear to be incorrectly assigned. Please revise both the site data table and the corresponding labels on the site plan to accurately reflect the correct orientation and ensure compliance with zoning setback requirements.

21.                     Please provide a fence and wall detail sheet that clearly illustrates the height, material, and design of the proposed fencing and walls. From the submitted plans, it appears that a chain link fence may be proposed. Please note that, per code, chain link fences are prohibited along arterial or collector streets. Therefore, if you are proposing a chain link fence along any frontage that abuts such a roadway, an alternative material will be required. The detail sheet should include the type of material, height, finishes, and any other relevant specifications. This will ensure that the proposed fencing complies with the City's development standards and can be accurately reviewed.

22.                     The NVAL (Non-Vehicular Access Line) must be clearly shown on the site plan and should match the NVAL line as depicted on the recorded plat. Please confirm that the proposed curb cut on the site plan does not encroach upon the NVAL line. If the curb cut does fall within the NVAL, a Plat Note Amendment will be required prior to approval. Based on the current information, the NVAL line appears to extend 100 feet along the west property line. Please review and revise the plans as necessary to ensure full compliance.

23.                     Provide the mounting height of the proposed light poles. The maximum height for lighting fixtures within 200 feet of a residential zoning district (the north property line) is 20’. For all other fixtures outside of this 200’ distance, the maximum height is 30’ (155.5401.D).

24.                     Provide a narrative that outlines how this project will achieve 12 sustainable development points, as referred to in section 155.5802.

25.                     A utility easement agreement form must be submitted at time of building permit for the pavement located within the utility easements on the east, west, and southern parts of the property (unless vacated). If these easements are vacated provide evidence of this.

26.                     Light poles must be at least 15’ from any existing or proposed trees per section 155.5203.B.2.g.i.c. Provide the 15’ radius for all light poles.

27.                     Please note that all signage will be reviewed as a separate permit and is not part of the site plan approval process. (Info Only).

28.                     The City of Pompano Beach’s Transportation Corridor Study Transformation Plan provides a typical cross-section required for West Atlantic Blvd. This cross-section requires the sidewalk to be increased to 10’-12’ wide. See page 69 of the Transformation Plan found on the Planning and Zoning Website. The applicant must widen the current sidewalk into the subject property to create a minimum sidewalk width of 10’ along Atlantic Blvd. With this sidewalk expansion, the applicant shall provide a sidewalk public access easement agreement to the City per section 155.5101.I.b.

29.                     Per Section 155.4219.H.3., A car wash or auto detailing use shall comply with the following standards:

                     The use shall be designed to ensure proper functioning of the site as related to vehicle stacking, circulation, and turning movements.

                     No overhead doors shall face the front lot line.

                     Each lane shall be covered with a permanent canopy which shall have a maximum clearance height of 14 feet above grade, except where state or federal law requires a higher clearance.

                     Outdoor activity may occur during business hours; such activity shall be limited to the washing, drying and other superficial detailing of the interior/exterior of the vehicles in accordance with an approved site plan.

                     Screening of this use shall meet the general requirements of Section 155.4219.A. Standards Applicable to Motor Vehicle Sales, Service, and Storage Uses.

                     A drive-through that is incorporated as an essential function of the operation shall be permitted by right as accessory to the principal business. Therefore, this use shall not be subject to the accessory use standards for Drive-Through Services within Code Section 155.4303.I. (Condition).

30.                     Provide confirmation from Engineering about the applicant’s responsibility to develop the portion of the road as part of the project. Since the road is currently incomplete, the applicant should be required to construct this segment in conjunction with their proposed development to ensure proper site access and continuity of infrastructure. Please confirm and include any comments received in this review.

 

PLEASE NOTE: Applications that require resubmission to the DRC have 45 days from the time of original DRC meeting in which to resubmit. Applications that fail to be resubmitted before the completion of these 45 days, or fail to receive a time extension from the Development Services Director, shall be considered withdrawn (§155.2304.B).