Attachments: 1. DRC Documents_10.04.2023.zip, 2. DRC Drawings_10.04.2023.zip, 3. DRC Documents_04.17.2024.zip, 4. DRC Drawings_04.17.2024.zip, 5. DRC Drawings_08.07.2024.zip, 6. DRC Documents_08.07.2024.zip, 7. DRC Drawings_09.18.2024.zip, 8. DRC Documents_09.18.2024.zip, 9. DRC Drawings_12.04.2024.zip, 10. DRC Documents_12.04.2024.zip
boardname
DEVELOPMENT REVIEW COMMITTEE
Meeting Date: DECEMBER 4, 2024

title
OLD CASTLE ACCESS AND SITE IMPROVEMENTS

projectinfo
Request: Minor Site Plan
P&Z# 23-12000032
Owner: Oldcastle APG South Inc
Project Location: 1200 NW 18th Street
Folio Number: 484227480010
Land Use Designation: I (Industrial)
Zoning District: I-1 (General Industrial)
Commission District: 4 (Beverly Perkins)
Agent: John Tice (jtice@galloherbert.com)
Project Planner: Diego Guevara (954-786-4310 / diego.guevara@copbfl.com)

otherinfo
Summary:
The applicant is requesting a Minor Site Plan approval for the construction of a new vehicular access from Andres Avenue to the property. The proposed driveway will be connected to the existing paved truck circulation. Also, a new pedestrian access will be provided and additional landscaping will be added. The project does not include any building addition or alteration.


Staff Conditions:
PLANNING
Max Wemyss | max.wemyss@copbfl.com
Status:


ZONING
Diego Guevara | diego.guevara@copbfl.com
Status: Pending Resubmit

Provide a written response addressing all comments issued.

1. There is not an updated narrative on the submittal file. Update the narrative as required, and list all the changes to the property in the scope of work, including the new driveway connecting the two abutting properties.
2. Sec. 155.5101.G.8.a - Vehicle Stacking Space: This section requires uses where vehicles queue up to access a service facility to provide a minimum number of stacking spaces established in Table 155.5101.G.8.a, Minimum Stacking Spaces for Drive-Through and Related Uses. Otherwise, add the following note to the Site Plan: "Gates must be open during hours of operation." The note must be added to the site plan. Otherwise, provide a site plan showing the location of the stacking line and the number of trucks occupying the stacking line. On a previous review, the applicant responded that the required note was added to the site plan; however...